Key Features
Add metal tube float flowmeter and needle valve, can manually adjust the flushing flow;
All parts required by Plan32 are assembled on the frame, with compact structure and convenient installation.
The FL external flushing system is purely mechanical and no explosion-proof issues consideration.
The system is equipped with a throttle valve, rotor flow meter, and pressure gauge, which can effectively control the flushing flow rate and accurately control the flushing pressure.
Equipped with a check valve to prevent excessive sealing chamber pressure or insufficient flushing fluid pressure causing backflow.
The system is integrated on a fixed bracket for easy transportation and installation.
Mainly used for API 682 Plan 32.
Can replace FTP,Safeunit SFP SUP,MFU Multi Flow Unit.
Specifications
Pressure | -0.1 ~ 4.0 MPa |
Temperature | 0 ℃ ~ 160 ℃ |
Material available | 304SS/316SS, etc |
Flushing medium | water/oil etc |
Assembly Chart
Downloads
+86-512-57997668
No.183 10B, Yinhe Road, High Tech Industrial Development Zone Changshu Suzhou, Jiangsu, China Postal Code: 215533